Postinterventional Assessment after Stent and Flow-Diverter Implantation Using CT: Influence of Spectral Image Reconstructions and Different Device Types

7Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND AND PURPOSE: CTA provides a noninvasive alternative technique to DSA in the follow-up after endovascular aneurysm treatment to evaluate aneurysm occlusion and exclude intraluminal narrowing after stent or flow-diverter implantation; however, assessability may be impeded by stent material artifacts. The objective of this in vitro study was to compare the visual assessability of different conventional stents and flow diverters as well as different reconstructions of dual-layer CT images. MATERIALS AND METHODS: Four conventional intracranial stents and 4 flow diverters were implanted in identical aneurysm phantoms. Conventional and monoenergetic images (40, 50, 60, 90, 120, 180 keV) were acquired to evaluate attenuation alteration, visible lumen diameter, and SNR. Image quality was rated subjectively by 2 independent radiologists using a 4-point Likert scale. RESULTS: Low kiloelectron volt (40-60 keV) monoenergetic reconstructions showed an improved SNR and an improved lumen density ratio compared with high kiloelectron volt reconstructions (90-180 keV) and conventional reconstructions, however without reaching significance compared with the latter. Assessment of the adjacent aneurysm and subjective evaluation was not affected by the imaging technique and stent type. Artifact susceptibility varied with the device used and increased among flow diverters. CONCLUSIONS: Low kiloelectron volt reconstructions improved the assessment of the stent lumen in comparison with high kiloelectron volt reconstructions. No significant improvement in image quality could be shown compared with conventional images. For some devices, iodine-specific reconstructions led to severe artifacts and are therefore not recommended. There was no relevant improvement in the assessability of the adjacent aneurysm.

References Powered by Scopus

The measurement of observer agreement for categorical data

60536Citations
N/AReaders
Get full text

Detector-based spectral CT with a novel dual-layer technology: principles and applications

222Citations
N/AReaders
Get full text

Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review

213Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The Use of Pointwise Encoding Time Reduction With Radial Acquisition MRA to Assess Middle Cerebral Artery Stenosis Pre- and Post-stent Angioplasty: Comparison With 3D Time-of-Flight MRA and DSA

5Citations
N/AReaders
Get full text

Ultra-high resolution CT angiography for the assessment of intracranial stents and flow diverters using photon counting detector CT

1Citations
N/AReaders
Get full text

High-resolution vessel wall imaging for quantitatively and qualitatively evaluating in-stent stenosis of intracranial aneurysms

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Zaeske, C., Hickethier, T., Borggrefe, J., Goertz, L., Dettmeyer, R., Schlamann, M., … Kabbasch, C. (2021). Postinterventional Assessment after Stent and Flow-Diverter Implantation Using CT: Influence of Spectral Image Reconstructions and Different Device Types. American Journal of Neuroradiology, 42(3), 516–523. https://doi.org/10.3174/AJNR.A6952

Readers' Seniority

Tooltip

Professor / Associate Prof. 2

40%

Researcher 2

40%

PhD / Post grad / Masters / Doc 1

20%

Readers' Discipline

Tooltip

Neuroscience 2

50%

Medicine and Dentistry 1

25%

Arts and Humanities 1

25%

Save time finding and organizing research with Mendeley

Sign up for free