Platelet secretion defects and Acquired von Willebrand syndrome in patients with ventricular assist devices

54Citations
Citations of this article
70Readers
Mendeley users who have this article in their library.

Abstract

Background--The number of implanted ventricular assist devices (VADs) has increased significantly recently. Bleeding, the most frequent complication, cannot be solely attributed to anticoagulation therapy. Acquired von Willebrand syndrome (AVWS) caused by increased shear stress is frequent in VAD patients and can increase the bleeding risk. The HeartMate III (HM III) is a novel left VAD featuring potential improvements over the HeartMate II. Methods and Results--In this study, we investigated the prevalence and onset of AVWS in 198 VAD patients. To our knowledge, this is the largest cohort of VAD patients whose longitudinal data on AVWS have been collected. We also analyzed whether AVWS is less severe in HM III patients than in HeartMate II patients. Because platelet dysfunction can raise the bleeding risk, we investigated platelet function in a subset of patients. In total, 198 VAD patients and 60 patients with heart transplants as controls were included in this study. The ratio of von Willebrand factor collagen binding capacity to von Willebrand factor:antigen, multimer analyses, and platelet function (especially secretion of a- and d-granules) were investigated. All 198 VAD patients developed AVWS. As soon as the VAD was explanted, the AVWS disappeared within hours. AVWS was less severe in the HM III patients than in the HeartMate II patients. The HM III patients had fewer bleeding symptoms. In addition, VAD patients exhibited a platelet a- and d-granule secretion defect. Conclusions--AVWS develops in VAD patients and may increase the bleeding risk. The HM III device causes less severe AVWS. Platelet secretion defects should be investigated in VAD patients because they also raise the bleeding risk.

References Powered by Scopus

Heart disease and stroke statistics - 2010 update: A report from the American heart association

3944Citations
N/AReaders
Get full text

Seventh INTERMACS annual report: 15,000 patients and counting

1157Citations
N/AReaders
Get full text

Von Willebrand's disease

416Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Physical Properties of Blood and their Relationship to Clinical Conditions

43Citations
N/AReaders
Get full text

Platelet Activation via Shear Stress Exposure Induces a Differing Pattern of Biomarkers of Activation versus Biochemical Agonists

39Citations
N/AReaders
Get full text

Acquired von Willebrand Syndrome and Platelet Function Defects during Extracorporeal Life Support (Mechanical Circulatory Support)

31Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Geisen, U., Brehm, K., Trummer, G., Berchtold-Herz, M., Heilmann, C., Beyersdorf, F., … Zieger, B. (2018). Platelet secretion defects and Acquired von Willebrand syndrome in patients with ventricular assist devices. Journal of the American Heart Association, 7(2). https://doi.org/10.1161/JAHA.117.006519

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 20

71%

Researcher 7

25%

Professor / Associate Prof. 1

4%

Readers' Discipline

Tooltip

Medicine and Dentistry 14

52%

Engineering 8

30%

Biochemistry, Genetics and Molecular Bi... 3

11%

Materials Science 2

7%

Save time finding and organizing research with Mendeley

Sign up for free