Membrane retention of the humic-like substances present in a soluble microbial products (SMP) suspension was studied by using a dead-end filtration system. The SMP suspension was extracted from the sludge of an enhanced biological phosphorus removal-membrane bioreactor. Our results showed that both adsorption and steric retention of the humic-like substances governed their transport through the membrane during the filtration. The adsorption, which followed pseudo-first order kinetics, did not cause substantial decline of permeate flux. The steric retention, on the other hand, formed a gel layer, which in turn led to a major decrease in the flux. The reduction of permeate flux was well predicted by cake filtration theory. Based on the adsorption and the steric retention, a new model was developed for predicting the overall membrane retention of the humic-like substances. The general trend of the modelled overall retention was in partial agreement with the experimental results.
CITATION STYLE
Poorasgari, E., Farsi, A., & Christensen, M. L. (2016). Fouling of a microfiltration membrane by humic-like substances: A mathematical approach to modelling permeate flux and membrane retention. Water Science and Technology, 73(12), 3033–3040. https://doi.org/10.2166/wst.2016.176