Comparative Biomechanical Behavior and Healing Profile of a Novel Thinned Wall Ultrahigh Molecular Weight Amorphous Poly- l -Lactic Acid Sirolimus-Eluting Bioresorbable Coronary Scaffold

4Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

Background - Mechanical strength of bioresorbable scaffolds (BRS) is highly dependent on strut dimensions and polymer features. To date, the successful development of thin-walled BRS has been challenging. We compared the biomechanical behavior and vascular healing profile of a novel thin-walled (115 μm) sirolimus-eluting ultrahigh molecular weight amorphous poly-l-lactic acid-based BRS (APTITUDE, Amaranth Medical [AMA]) to Absorb (bioresorbable vascular scaffold [BVS]) using different experimental models. Methods and Results - In vitro biomechanical testing showed no fractures in the AMA-BRS when overexpanded 1.3 mm above nominal dilatation values (≈48%) and lower number of fractures on accelerated cycle testing over time (at 21 K cycles=20.0 [19.5-20.5] in BVS versus 4.0 [3.0-4.3] in AMA-BRS). In the healing response study, 35 AMA-BRS and 23 BVS were implanted in 58 coronary arteries of 23 swine and followed-up to 180 days. Scaffold strut healing was evaluated in vivo using weekly optical coherence tomography analysis. At 14 days, the AMA-BRS demonstrated a higher percentage of embedded struts (71.0% [47.6, 89.1] compared with BVS 40.3% [20.5, 63.2]; P=0.01). At 21 days, uncovered struts were still present in the BVS group (3.8% [2.1, 10.2]). Histopathology revealed lower area stenosis (AMA-BRS, 21.0±6.1% versus BVS 31.0±4.5%; P=0.002) in the AMA-BRS at 28 days. Neointimal thickness and inflammatory scores were comparable between both devices at 180 days. Conclusions - A new generation thinned wall BRS displayed a more favorable biomechanical behavior and strut healing profile compared with BVS in normal porcine coronary arteries. This novel BRS concept has the potential to improve the clinical outcomes of current generation BRS.

References Powered by Scopus

Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine model

1091Citations
N/AReaders
Get full text

In-stent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia

840Citations
N/AReaders
Get full text

Everolimus-eluting bioresorbable scaffolds for coronary artery disease

587Citations
N/AReaders
Get full text

Cited by Powered by Scopus

In vitro mechanical behavior and in vivo healing response of a novel thin-strut ultrahigh molecular weight poly-L-lactic acid sirolimus-eluting bioresorbable coronary scaffold in normal swine

9Citations
N/AReaders
Get full text

Safety and efficacy of new-generation coronary bioresorbable scaffolds

2Citations
N/AReaders
Get full text

Early scaffold strut coverage in ultra-high molecular weight amorphous PLLA sirolimus-eluting bioresorbable scaffolds: Impact of strut thickness assessed in normal porcine coronary arteries

1Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Cheng, Y., Gasior, P., Xia, J. G., Ramzipoor, K., Lee, C., Estrada, E. A., … Granada, J. F. (2017). Comparative Biomechanical Behavior and Healing Profile of a Novel Thinned Wall Ultrahigh Molecular Weight Amorphous Poly- l -Lactic Acid Sirolimus-Eluting Bioresorbable Coronary Scaffold. Circulation: Cardiovascular Interventions, 10(7). https://doi.org/10.1161/CIRCINTERVENTIONS.117.005116

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 10

71%

Researcher 3

21%

Lecturer / Post doc 1

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

67%

Materials Science 1

11%

Chemistry 1

11%

Engineering 1

11%

Save time finding and organizing research with Mendeley

Sign up for free