Cánula nasal de alto flujo en lactantes: Experiencia en una unidad de paciente crítico

6Citations
Citations of this article
96Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Introduction: The high flow nasal cannula (HFNC) is a method of respiratory support that is increasingly being used in paediatrics due to its results and safety. Objective: To determine the efficacy of HFNC, as well as to evaluate the factors related to its failure and complications associated with its use in infants. Patients and method: An analysis was performed on the demographic, clinical, blood gas, and radiological data, as well as the complications of patients connected to a HFNC in a critical care unit between June 2012 and September 2014. A comparison was made between the patients who failed and those who responded to HFNC. A failure was considered as the need for further respiratory support during the first 48 hours of connection. The Kolmogorov Smirnov, Mann-Whitney U, chi squared and the Exact Fisher test were used, as well as correlations and a binary logistic regression model for P ≤ .05. Results: The study included 109 patients, with a median age and weight: 1 month (0.2-20 months) and 3.7 kg (2-10 kg); 95 percentile: 3.7 months and 5.7 kg, respectively. The most frequent diagnosis and radiological pattern was bronchiolitis (53.2%) and interstitial infiltration (56%). Around 70.6% responded. There was a significant difference between failure and response in the diagnosis (P = .013), radiography (P = 018), connection context (P < .0001), pCO2 (median 40.7 mmHg [15.4-67 mmHg] versus 47.3 mmHg [28.6-71.3 mmHg], P = .004) and hours on HFNC (median 60.75 hrs [5-621.5 hrs] versus 10.5 hrs [1-29 hrs], P < .0001). The OR of the PCO2 ≥ 55 mmHg for failure was 2.97 (95% CI; 1.08-8.17; P = .035). No patient died and no complications were recorded. Conclusion: The percentage success observed was similar to that published. In this sample, the failure of HFNC was only associated with an initial pCO2 ≥ 55 mmHg. On there being no complications reported as regards it use, it is considered safe, although a randomised, controlled, multicentre study is required to compare and contrast these results.

Cite

CITATION STYLE

APA

Wegner A., A., Cespedes F., P., Godoy M., M. L., Erices B., P., Urrutia C., L., Venthur U., C., … Urrutia S., E. (2015). Cánula nasal de alto flujo en lactantes: Experiencia en una unidad de paciente crítico. Revista Chilena de Pediatria, 86(3), 173–181. https://doi.org/10.1016/j.rchipe.2015.06.003

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free