Estimation of Tidal Volume during Exercise Stress Test from Wearable-Device Measures of Heart Rate and Breathing Rate

5Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

Tidal volume (TV), defined as the amount of air that moves in or out of the lungs with each respiratory cycle, is important in evaluating the respiratory function. Although TV can be reliably measured in laboratory settings, this information is hardly obtainable under everyday living conditions. Under such conditions, wearable devices could provide valuable support to monitor vital signs, such as heart rate (HR) and breathing rate (BR). The aim of this study was to develop a model to estimate TV from wearable-device measures of HR and BR during exercise. HR and BR were acquired through the Zephyr Bioharness 3.0 wearable device in nine subjects performing incremental cycling tests. For each subject, TV during exercise was obtained with a metabolic cart (Cosmed). A stepwise regression algorithm was used to create the model using as possible predictors HR, BR, age, and body mass index; the model was then validated using a leave-one-subject-out cross-validation procedure. The performance of the model was evaluated using the explained variance (R2), obtaining values ranging from 0.65 to 0.72. The proposed model is a valid method for TV estimation with wearable devices and can be considered not subject-specific and not instrumentation-specific.

References Powered by Scopus

The physiological basis and clinical significance of lung volume measurements

111Citations
N/AReaders
Get full text

Spirometry: Step by step

110Citations
N/AReaders
Get full text

Optoelectronic Plethysmography in Clinical Practice and Research: A Review

88Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Wearable and Portable Devices for Acquisition of Cardiac Signals while Practicing Sport: A Scoping Review

18Citations
N/AReaders
Get full text

Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System

1Citations
N/AReaders
Get full text

A Comprehensive Review on Wearable Smart Respiratory Monitoring Shirt in COPD Patients

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Sbrollini, A., Catena, R., Carbonari, F., Bellini, A., Sacchetti, M., Burattini, L., & Morettini, M. (2022). Estimation of Tidal Volume during Exercise Stress Test from Wearable-Device Measures of Heart Rate and Breathing Rate. Applied Sciences (Switzerland), 12(11). https://doi.org/10.3390/app12115441

Readers over time

‘22‘23‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Researcher 1

33%

Readers' Discipline

Tooltip

Biochemistry, Genetics and Molecular Bi... 2

40%

Computer Science 1

20%

Immunology and Microbiology 1

20%

Engineering 1

20%

Save time finding and organizing research with Mendeley

Sign up for free
0