Feasibility of portable capnometer for mechanically ventilated preterm infants in the delivery room

0Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This study aimed to determine whether a specific portable capnometer (EMMA™) can facilitate the maintenance of an appropriate partial pressure of arterial carbon dioxide (PaCO2) in intubated preterm infants in the delivery room. This study included preterm infants with a gestational age of 26 + 0 to 31 + 6 weeks who required intubation in the delivery room. We prospectively identified 40 infants who underwent the EMMA™ monitoring intervention group and 43 infants who did not undergo monitoring (historical control group). PaCO2 was evaluated either at admission in the neonatal intensive care unit or at 2 h after birth. The proportion of infants with an appropriate PaCO2 (35–60 mmHg) was greater in the intervention group than in the control group (80% vs. 42%; p = 0.001). There were no significant differences in the rate of accidental extubation (5.0% vs. 7.0%, p = 1.00) or in the proportion of infants with an appropriate PaCO2 among infants whose birth weight was < 1000 g (54% vs. 40%, p = 0.49). However, among infants whose birth weight was ≥ 1000 g, the PaCO2 tended to be more appropriate in the intervention group than in the control group (93% vs. 44%; p < 0.001). Conclusion: The EMMA™ facilitated the maintenance of an appropriate PaCO2 for mechanically ventilated preterm infants, especially infants with birth weight ≥1000 g, in the delivery room.What is Known:• An inappropriate partial pressure of arterial carbon dioxide has been associated with intraventricular hemorrhage in preterm infants.• There is a need to appropriately control the partial pressure of arterial carbon dioxide in preterm infants.What is New:• This is the first report regarding the feasibility of a portable capnometer, the EMMA™, in the delivery room.• The EMMA™ may be considered a feasible monitoring device in the delivery room for intubated preterm infants, especially infants with birth weight ≥1000 g.

Cite

CITATION STYLE

APA

Hotta, M., Hirata, K., Nozaki, M., Mochizuki, N., Hirano, S., & Wada, K. (2022). Feasibility of portable capnometer for mechanically ventilated preterm infants in the delivery room. European Journal of Pediatrics, 181(2), 629–636. https://doi.org/10.1007/s00431-021-04246-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free