A randomized study of coronary artery bypass surgery performed with the Resting Heart™ System utilizing a low vs a standard dosage of heparin

11Citations
Citations of this article
95Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: Allogeneic blood transfusion and reoperation for postoperative bleeding after the coronary artery bypass grafting have a negative impact on the patient outcome. This study aimed at evaluating the effects of reduced doses of heparin and protamine on the patient outcome, using a heparin-coated mini-cardiopulmonary bypass (CPB) system.METHODS: Sixty patients undergoing elective first-time CPB were prospectively randomized either to have a reduced systemic heparinization [activated clotting time (ACT) = 250 s] or to a control group perfused with a full heparin dose (ACT = 420 s). Blood transfusions, ventilation time, early postoperative bleeding, ICU stay, reoperations for bleeding, postoperative cognitive status and the level of mobilization were registered.RESULTS: Twenty-nine patients were randomized to the control group, 27 patients to the low-dose group and 4 patients were excluded because of protocol violations. Four patients in the control group received a total of 10 units of packed red blood cells, and in the low-dose group, no transfusions were given, P = 0.046. No patient was reoperated because of bleeding. The ICU stay was significantly shorter in the low-dose group (8.4 vs 13.7 h, P = 0.020), less dependent on oxygen on the first postoperative day (78 vs 97%, P = 0.034), better mobilized (89 vs 59%, P = 0.006) and had less pain (visual analogue scale 2.0 vs 3.5, P = 0.019) compared with the control group.CONCLUSIONS: The use of a mini-CPB system combined with a low dose of heparin reduced the need for blood transfusions and may facilitate the faster mobilization of the patients. © 2012 The Author 2012. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Cite

CITATION STYLE

APA

Nilsson, J., Scicluna, S., Malmkvist, G., Pierre, L., Algotsson, L., Paulsson, P., … Johnsson, P. (2012). A randomized study of coronary artery bypass surgery performed with the Resting HeartTM System utilizing a low vs a standard dosage of heparin. Interactive Cardiovascular and Thoracic Surgery, 15(5), 834–839. https://doi.org/10.1093/icvts/ivs345

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free