Effectivity of low intensity pulsed ultrasound on rabbit femur post orif plate and screw

0Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.
Get full text

Abstract

A femoral fracture is a trauma with a high mortality rate. Long bone fracture cases frequently related to missing bone segments, that can disrupt the bone healing. The process of defect fracture healing requires internal and external mechanical stimulation, external stimulation can be stimulated using low-intensity pulsed ultrasounds. Clinical studies have shown a significant positive effect from LIPUS in the treatment of non-union fractures and accelerated fracture repair compared to fractures treated with a placebo of 38%. The purpose of this study was to determine the effectiveness of LIPUS on the healing of defect femoral fractures in rabbit post-ORIF plate and screw-based on radiological measurements. This study is a comparative, unpaired laboratory experimental study with two treatment groups and one control group. The treatment group consists of group I that was given LIPUS 30 mW/cm2 for 10 minutes per day and Group II 30 mW/cm2 for 20 minutes per day, Group III without LIPUS treatment as the control group. Radiological assessment was performed to assess callus formation based on the Tiedemann score. After that data is collected, data editing, coding, entry were carried out and analyzed statistically. There were significant differences between treatment group and control group towards callus diameter formation, between-group I, II and control with mean of Tiedemann in each group 97.76; 169.83; 76.88; with p-value < 0.05. LIPUS can enhance fracture healing in rabbit femur defects based on radiography measurement.

References Powered by Scopus

Acceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound

797Citations
N/AReaders
Get full text

Accelerated healing of distal radial fractures with the use of specific, low-intensity ultrasound: A multicenter, prospective, randomized, double- blind, placebo-controlled study

514Citations
N/AReaders
Get full text

The use of low-intensity ultrasound to accelerate the healing of fractures

338Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ismiarto, Y. D., Budi, M. N. S., & Mahyudin. (2020). Effectivity of low intensity pulsed ultrasound on rabbit femur post orif plate and screw. Biomedical and Pharmacology Journal, 13(1), 489–496. https://doi.org/10.13005/BPJ/1910

Readers over time

‘20‘21‘2202468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 1

50%

Researcher 1

50%

Readers' Discipline

Tooltip

Medicine and Dentistry 4

67%

Pharmacology, Toxicology and Pharmaceut... 1

17%

Social Sciences 1

17%

Save time finding and organizing research with Mendeley

Sign up for free
0