OCRA (OCcupational Repetitive Action) is currently one of the most widespread procedures for assessing biomechanical risks related to upper limb repetitive movements. Frequency factor of the technical actions represents one of the OCRA elements. Actually, the frequency factor computation is based on workcycle video analysis, which is time-consuming and may lead to up to 30% of intra-operator variability. This paper aims at proposing an innovative procedure for the automatic counting of dynamic technical actions on the basis of inertial data. More specifically, a threshold-based algorithm was tested in four industrial case studies, involving a cohort of 20 workers. Nine combinations of the algorithm were tested by varying threshold values related to time and amplitude. The computation of frequency factor showed an average relative error lower than 5.7% in all industrial-based case studies after the appropriate selection of the time and amplitude threshold values. These findings open the possibility to use the threshold-based algorithm proposed here for the automatic computation of OCRA frequency factor, avoiding the time efforts in video analysis.
CITATION STYLE
Taborri, J., Bordignon, M., Marcolin, F., Bertoz, A., Donati, M., & Rossi, S. (2020). On the OCRA measurement: Automatic computation of the dynamic technical action frequency factor. Sensors (Switzerland), 20(6). https://doi.org/10.3390/s20061643
Mendeley helps you to discover research relevant for your work.