Comparison of culture methods for monitoring Legionella species in hospital potable water systems and recommendations for standardization of such methods

102Citations
Citations of this article
68Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A lack of standardization of environmental monitoring techniques for Legionella spp. complicates the interpretation of results and comparisons of results from different institutions. A comparative assessment of techniques recommended by the Centers for Disease Control and Prevention, the Hygiene Institute (Graz, Austria), and our laboratory was performed. Variables investigated were sampling method (swabbing and collection of water samples [250 ml] before and after swabbing), method of concentration (none, filtration, and centrifugation), acid buffer treatment (no acid treatment, treatment for 3 min, and treatment for 15 min), and choice of medium (five formulations of buffered charcoal yeast extract agar with glycine, vancomycin, polymyxin B, anisomycin, or cycloheximide). Thirty-three sites in seven hospital buildings were studied. Recovery by swab correlated with recovery from water after swabbing (P < 0.05). However, the quantity of Legionella spp. recovered from swab specimens (mean, 3.0 x 104 CFU per swab) was greater than that recovered from water (mean, 4.7 x 103 CFU/250 ml). Filtration resulted in recovery rates (mean, 5.2 x 103 CFU/250 ml) higher than those by centrifugation (mean, 2.3 x 103 CFU/250 ml). Three minutes of acid buffer treatment to reduce overgrowth by commensal flora did not improve selectivity or sensitivity for Legionella spp. if glycine-containing selective media were used. Fifteen minutes of acid buffer treatment reduced recovery compared with that after a 3-min treatment. All glycine-containing media tested effectively inhibited background flora, but one selective medium containing dyes, glycine, vancomycin, and polymyxin B (DGVP) resulted in the greatest quantitative recovery of Legionella pneumophila. Use of buffered charcoal yeast extract agar and the acid buffer treatment gave the greatest recovery of non-pneumophila species. A standardized protocol with an emphasis on the culturing of swab samples is presented.

Cite

CITATION STYLE

APA

Ta, A. C., Stout, J. E., Yu, V. L., & Wagener, M. M. (1995). Comparison of culture methods for monitoring Legionella species in hospital potable water systems and recommendations for standardization of such methods. Journal of Clinical Microbiology, 33(8), 2118–2123. https://doi.org/10.1128/jcm.33.8.2118-2123.1995

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free