Feasibility, safety, and efficacy of real-time three-dimensional transoesophageal echocardiography for guiding device closure of interatrial communications: Initial clinical experience and impact on radiation exposure

35Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.

Abstract

Aims Our aim was to assess the feasibility and safety of real-time (RT) three-dimensional (3D) transoesophageal echocardiography (TEE) for guiding transcatheter closure of interatrial communications and to evaluate its additional benefit over conventional 2D TEE in reducing radiation exposure for the patient. Methods and results Twenty-five patients undergoing device closure of their interatrial defect had the procedure guided by fluoroscopy, 2D TEE, and RT 3D TEE. We retrospectively compared this group with a historical control group in which interventional guidance was performed using fluoroscopy and 2D TEE alone. The application of RT 3D TEE allowed safe device deployment in all patients without any complications, resulting in a reduction of mean fluoroscopy time (10 ± 6 to 6 ± 4 min, P < 0.01), mean dose area product (DAP) (964 ± 628 to 535 ± 464 cGy cm2, P < 0.01), and mean DAP per individual body surface area (494 ± 317 to 273 ± 221 cGy cm2/m2, P < 0.01). Conclusion RT 3D TEE as an adjunct to 2D TEE is a feasible and safe tool to guide transcatheter device closure of interatrial communications, resulting in a reduction of radiation exposure. These data indicate that RT 3D TEE can be used to safely monitor interatrial defect closure in clinical routine.

References Powered by Scopus

Early and late complications associated with transcatheter occlusion of secundum atrial septal defect

548Citations
N/AReaders
Get full text

Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism

336Citations
N/AReaders
Get full text

Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): Multicentre UK experience

302Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Atrial septal defects

260Citations
N/AReaders
Get full text

Short and long term complications of device closure of atrial septal defect and patent foramen ovale: Meta-analysis of 28,142 patients from 203 studies

133Citations
N/AReaders
Get full text

Left atrial appendage closure guided by integrated echocardiography and fluoroscopy imaging reduces radiation exposure

46Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Balzer, J., Van Hall, S., Rassaf, T., Böring, Y. C., Franke, A., Lang, R. M., … Kühl, H. P. (2010). Feasibility, safety, and efficacy of real-time three-dimensional transoesophageal echocardiography for guiding device closure of interatrial communications: Initial clinical experience and impact on radiation exposure. European Journal of Echocardiography, 11(1), 1–8. https://doi.org/10.1093/ejechocard/jep116

Readers' Seniority

Tooltip

Researcher 5

36%

PhD / Post grad / Masters / Doc 4

29%

Professor / Associate Prof. 3

21%

Lecturer / Post doc 2

14%

Readers' Discipline

Tooltip

Medicine and Dentistry 14

74%

Agricultural and Biological Sciences 3

16%

Philosophy 1

5%

Arts and Humanities 1

5%

Save time finding and organizing research with Mendeley

Sign up for free