Mini-beam collimator enables microcrystallography experiments on standard beamlines

82Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a standard beam from an undulator source, 25-50 m (FWHM) in the vertical and 50-100 m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 m 65 m at the sample position. To meet growing user demand for beams to study samples of 10 m or less, a mini-beam apparatus was developed that conditions the focused beam to either 5 m or 10 m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam. © 2009 International Union of Crystallography Printed in Singapore - All rights reserved.

Cite

CITATION STYLE

APA

Fischetti, R. F., Xu, S., Yoder, D. W., Becker, M., Nagarajan, V., Sanishvili, R., … Smith, J. L. (2009). Mini-beam collimator enables microcrystallography experiments on standard beamlines. Journal of Synchrotron Radiation, 16(2), 217–225. https://doi.org/10.1107/S0909049508040612

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free