Magnetic resonance imaging arthrography following type II superior labrum from anterior to posterior repair: interobserver and intraobserver reliability

  • Lo I
  • Kurji H
  • Ono Y
  • et al.
N/ACitations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND Arthroscopic repair of type II superior labrum from anterior to posterior (SLAP) lesions is a common surgical procedure. However, anatomic healing following repair has rarely been investigated. The intraobserver and interobserver reliability of magnetic resonance imaging arthrography (MRA) following type II SLAP repair has not previously been investigated. This is of particular interest due to recent reports of poor clinical results following type II SLAP lesion repair. PURPOSE To evaluate the MRA findings following arthroscopic type II SLAP lesion repair and determine its intraobserver and interobserver reliability. STUDY DESIGN Cohort study (diagnosis), Level of Evidence, 2. METHODS Twenty-five patients with an isolated type II SLAP lesion (confirmed via diagnostic arthroscopy) underwent standard suture anchor-based repair. At a mean of 25.2 months post-operatively, patients underwent a standardized MRA protocol to investigate the integrity of the repair. MRAs were independently reviewed by two radiologists and a fellowship trained shoulder surgeon. The outcomes were classified as healed SLAP repair or re-torn SLAP repair. RESULTS On average, 54% of MRAs were interpreted as healed SLAP repairs while 46% of MRAs were interpreted as having a re-torn SLAP repair. Overall, only 43% of the studies had 100% agreement across all interpretations. The intraobserver reliability ranged from 0.71 to 0.81 while the interobserver reliability between readers ranged from 0.13 to 0.44 (Table 1). CONCLUSION The intraobserver agreement of MRA in the evaluation of type II SLAP repair was substantial to excellent. However, the interobserver agreement of MRA was poor to fair. As a result, the routine use of MRA in the evaluation of type II SLAP lesion repair should be utilized with caution. A global evaluation of the patient, including detailed history and physical examination, is paramount in determining the cause of failure and one should not rely on MRA alone.

Cite

CITATION STYLE

APA

Lo, I., Kurji, H., Ono, Y., Nelson, A., More, K., Wong, B., … Thornton, G. (2015). Magnetic resonance imaging arthrography following type II superior labrum from anterior to posterior repair: interobserver and intraobserver reliability. Open Access Journal of Sports Medicine, 329. https://doi.org/10.2147/oajsm.s79722

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free