Abstract

Atomic force microscopy (AFM) cantilever is a widely used end effector for precise force sensing and micro-nanomanipulation at small scale. However, in current researches, the effect of the cantilever tip on the force sensing and manipulation accuracy is rarely considered. In this paper, we investigate how the tip size of the end effector affects the measurement accuracy of the cell adhesion force. First, several end effectors with different tip sizes are fabricated from the same AFM cantilever via focused ion beam (FIB) etching. Then, the single cell detachment force is measured at the same experiment condition by these end effectors, respectively. The results indicate that the sensed adhesion force is susceptible to the tip size of the end effector obviously. In addition, the precision of cell manipulation is also regulated by the contact area between the cell and end effector greatly. These findings will benefit our in-depth understanding on the force interaction at small scale and will provide valid reference for the development of high-precision force sensor and manipulation.

References Powered by Scopus

Migration of tumor cells in 3D matrices is governed by matrix stiffness along with cell-matrix adhesion and proteolysis

973Citations
N/AReaders
Get full text

Microrobots for micrometer-size objects in aqueous media: Potential tools for single-cell manipulation

534Citations
N/AReaders
Get full text

Electrothermally activated SU-8 microgripper for single cell manipulation in solution

352Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Advanced mechanical and electrical characterization of piezoelectric ZnO nanowires for electro-mechanical modeling of enhanced performance sensors

10Citations
N/AReaders
Get full text

In situ bending and recovery characterization of hollow glass nanoneedle based on nanorobotic manipulation

5Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Shen, Y. (2015). Effect of the tip size on AFM cantilever based force sensor. Journal of Sensors, 2015. https://doi.org/10.1155/2015/926594

Readers over time

‘15‘16‘17‘18‘19‘20‘21‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 10

77%

Professor / Associate Prof. 2

15%

Researcher 1

8%

Readers' Discipline

Tooltip

Engineering 9

64%

Physics and Astronomy 3

21%

Materials Science 1

7%

Social Sciences 1

7%

Save time finding and organizing research with Mendeley

Sign up for free
0