Short-Term Repeatability of Noninvasive Aortic Pulse Wave Velocity Assessment: Comparison between Methods and Devices

54Citations
Citations of this article
81Readers
Mendeley users who have this article in their library.
Get full text

Abstract

BACKGROUND Aortic pulse wave velocity (PWV) is an indirect index of arterial stiffness and an independent cardiovascular risk factor. Consistency of PWV assessment over time is thus an essential feature for its clinical application. However, studies providing a comparative estimate of the reproducibility of PWV across different noninvasive devices are lacking, especially in the elderly and in individuals at high cardiovascular risk. METHODS Aimed at filling this gap, short-term repeatability of PWV, estimated with 6 different devices (Complior Analyse, PulsePen-ETT, PulsePen-ET, SphygmoCor Px/Vx, BPLab, and Mobil-O-Graph), was evaluated in 102 high cardiovascular risk patients hospitalized for suspected coronary artery disease (72 males, 65 ± 13 years). PWV was measured in a single session twice, at 15-minute interval, and its reproducibility was assessed though coefficient of variation (CV), coefficient of repeatability, and intraclass correlation coefficient. RESULTS The CV of PWV, measured with any of these devices, was <10%. Repeatability was higher with cuff-based methods (BPLab: CV = 5.5% and Mobil-O-Graph: CV = 3.4%) than with devices measuring carotid-femoral PWV (Complior: CV = 8.2%; PulsePen-TT: CV = 8.0%; PulsePen-ETT: CV = 5.8%; and SphygmoCor: CV = 9.5%). In the latter group, PWV repeatability was lower in subjects with higher carotid-femoral PWV. The differences in PWV between repeated measurements, except for the Mobil-O-Graph, did not depend on short-term variations of mean blood pressure or heart rate. CONCLUSIONS Our study shows that the short-term repeatability of PWV measures is good but not homogenous across different devices and at different PWV values. These findings, obtained in patients at high cardiovascular risk, may be relevant when evaluating the prognostic importance of PWV.

Cite

CITATION STYLE

APA

Grillo, A., Parati, G., Rovina, M., Moretti, F., Salvi, L., Gao, L., … Salvi, P. (2018). Short-Term Repeatability of Noninvasive Aortic Pulse Wave Velocity Assessment: Comparison between Methods and Devices. American Journal of Hypertension, 31(1), 80–88. https://doi.org/10.1093/ajh/hpx140

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free