Computation of ground vibration around pier by using axisymmetric finite element method

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

We conducted on a study on a method of calculating ground vibration around a girder-type viaduct. This work focuses on the motion of the pier caused by the passing trains. Vibration acceleration in the pier at time of train passage was measured. Measurements revealed that vibration consisted chiefly of vertical translational behavior and rotational behavior around the horizontal axis. Analysis of ground vibration by axisymmetric finite element method considering these motions as excitation force characteristics was carried out. It was confirmed that the calculation results reproduce the ground vibration in the frequency range below 40 Hz.

Cite

CITATION STYLE

APA

Kaneda, J., Ikemoto, H., Ishii, T., & Saitoh, K. (2018). Computation of ground vibration around pier by using axisymmetric finite element method. In Notes on Numerical Fluid Mechanics and Multidisciplinary Design (Vol. 139, pp. 571–583). Springer Verlag. https://doi.org/10.1007/978-3-319-73411-8_45