Laboratory study of the collection efficiency of submicron aerosol particles by cloud droplets-Part II: Influence of electric charges

9Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

A new In-Cloud Aerosol Scavenging Experiment (In-CASE) has been developed to measure the collection effi ciency (CE) of submicron aerosol particles by cloud droplets. Droplets fall at their terminal velocity through a 1 m high chamber in a laminar flow containing aerosol particles. At the bottom of the In-CASE chamber, the droplet train is sep arated from the aerosol particles flow, and the droplets are collected in an impaction cup, whereas aerosol particles are deposited on a high-efficiency particulate air (HEPA) filter. The collected droplets and the filter are then analysed by flu orescence spectrometry since the aerosol particles are atom ised from a sodium fluorescein salt solution (C20H10Na2O5). In-CASE fully controls all the parameters which affect the CE the droplets and aerosol particles size distributions are monodispersed, the electric charges of droplets and aerosol particles are known and set, and the relative humidity is indi rectly controlled via the chamber s temperature. This paper details the In-CASE setup and the dataset of 70 measure ments obtained to study the impact of the electric charges on CE. For this purpose, droplets and particles charges are con trolled through two charging systems developed in this work both chargers are detailed below. The droplet charge varies from-3.0 × 104 ± 1.4 × 103 to +9.6 × 104 ± 4.3 × 103 ele mentary charges, while the particle charge ranges from zero to-90 ± 9 elementary charges depending on the particle ra dius. A droplet radius of 48.5 ± 1.1 μm has been considered for four particle dry radii between 100 and 250 nm while the relative humidity level during experiments is 95.1 ± 0.2 %. The measurements are then compared to theoretical models from literature showing good agreement.

Cite

CITATION STYLE

APA

Dépée, A., Lemaitre, P., Gelain, T., Monier, M., & Flossmann, A. (2021). Laboratory study of the collection efficiency of submicron aerosol particles by cloud droplets-Part II: Influence of electric charges. Atmospheric Chemistry and Physics, 21(9), 6963–6984. https://doi.org/10.5194/acp-21-6963-2021

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free