Impact of a Swept Source-Optical Coherence Tomography Device on Efficiency in Cataract Evaluation and Surgery: A Time-and-Motion Study

2Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: This study aims to assess the time impact of ARGOS® (image-guided swept-source optical coherence tomography biometer integrated with operating room (OR) technologies (SS-OCT w/ORT)) compared to LENSTAR LS 900 (optical low-coherence reflectometry (OLCR)), IOLMaster 500 (partial coherence interferometry (PCI)), and IOLMaster 700 (SS-OCT) on efficiency in the cataract evaluation and surgery. Patients and Methods: Data from 212 patients (two study sites) who underwent evaluation and/or cataract surgery were collected. The primary objective was to compare the performance of four biometers; statistical analyses were conducted to compare 1) biometer measurement times for all patients (ANOVA w/post-hoc Dunnett’s test) and stratified by cataract density (ANOVA) and 2) rate of biometer acquisition failure (Chi-square test w/post-hoc Bonferroni correction). Real-world observational data collected were then used to develop a practice-based time-efficiency model to demonstrate the combined effect that adopting an SS-OCT w/ORT has on a practice’s cataract workflow. Real-world data inputs included assessment of patient’s eyes’ cataract grade density, time taken for optical biometry, Manual A-scan (ultrasound biometer) when acquisition failed, and measurement times associated with other devices used in cataract evaluation and surgery. Results: For 208 patients (56% non-dense, 44% dense), the SS-OCT w/ORT biometer had a 0% acquisition failure (SS-OCT: 3% (p = 0.05); OLCR: 5% (p = 0.004); PCI: 15% (p < 0.0001)) and an average time savings of 30 seconds/patient compared to the other biometers in this study (p < 0.05). When acquisition failed, ultrasound biometry resulted in an additional 2.5 minutes/patient. For a cohort of 1000 patients, an SS-OCT w/ORT and an image-guidance system adopted at a practice using an SS-OCT, femtosecond laser, and intraoperative aberrometer offer up to 58% efficiency gain across the cataract workflow. Conclusion: Results from this study demonstrate an SS-OCT w/ORT’s efficiencies in cataract evaluation and surgery driven by faster measurement times, reducing the need for ultrasound biometry, and its integration benefits with other devices.

Cite

CITATION STYLE

APA

Multack, S., Pan, L. C., Timmons, S. K., Pan, S. M., Woodard, L., Datar, M., … Babu, R. (2023). Impact of a Swept Source-Optical Coherence Tomography Device on Efficiency in Cataract Evaluation and Surgery: A Time-and-Motion Study. Clinical Ophthalmology, 17, 1–13. https://doi.org/10.2147/OPTH.S384545

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free