A practical comparative analysis of single-pass and double-pass amplification schemes of 1480-nm pumped Er3+-doped fiber amplifier (EDFA) is presented in this paper. This comparison is carried out with an input signal from 0 dBm to -40 dBm at 140-mW pump power. The critical input power of -25 dBm is obtained in order to determine the optimized performance between single-pass and double-pass amplifiers. The double-pass EDFA gives a better performance for small signal powers of less than -25 dBm, while the single-pass EDFA performs better for higher signal powers of greater than -25 dBm. © 2004 Wiley Periodicals, Inc.

Cite

CITATION STYLE

APA

Naji, A. W., Abidin, M. S. Z., Kassir, A. M., Al-Mansoori, M. H., Abdullah, M. K., & Mahdi, M. A. (2004). Trade-off between single and double pass amplification schemes of 1480-nm pumped EDFA. Microwave and Optical Technology Letters, 43(1), 38–40. https://doi.org/10.1002/mop.20368