Bilateral bispectral index monitoring during and after electroconvulsive therapy compared with magnetic seizure therapy for treatment-resistant depression

21Citations
Citations of this article
99Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background Electroconvulsive therapy (ECT) is a highly effective and established treatment for depression. Magnetic seizure therapy (MST) has recently been developed and seems equally effective while associated with fewer side-effects. Both require general anaesthesia, which could be quantified using the bispectral index (BIS). We compared ECT and MST with respect to recovery times, left-sided BIS, and left-right differences in BIS. Methods In this prospective, observational study, we enrolled 10 successive patients receiving ECT and 10 patients undergoing MST. Anaesthesia was performed with propofol and monitored with a bilateral BIS sensor. The seizure was elicited when the BIS was within a range from 50 to 60. The time to eye opening was measured and bilateral BIS were recorded for 10 min after seizure induction. Results A comparable anaesthetic depth was observed in the ECT and MST groups at baseline [mean (standard deviation, sd) BIS values of 94.1 (4.1) and 95.5 (3.0), respectively] and before seizure induction [mean (sd) BIS values of 52.3 (9.6) and 55.2 (10.3), respectively]. Post-ictally, MST patients opened their eyes significantly earlier than ECT patients [3.0 (1.0) vs 6.7 (1.3) min, P<0.001]. They showed a significantly higher BIS at 2 min after seizure induction [69.2 (10.1) vs 50.9 (15.9), P=0.003], and this difference was still present at 10 min after seizure induction [BIS 81.5 (6.5) vs 68.0 (16.4), P<0.001]. Significant differences between the left and right BIS were observed in neither the ECT nor the MST group. Conclusions At a comparable anaesthetic depth, MST is superior to ECT in terms of post-ictal recovery, which is correctly reflected by higher post-ictal BIS values. Unilateral BIS monitoring is sufficient to monitor anaesthetic depth in ECT and MST patients. © The Author [2013].

Cite

CITATION STYLE

APA

Soehle, M., Kayser, S., Ellerkmann, R. K., & Schlaepfer, T. E. (2014). Bilateral bispectral index monitoring during and after electroconvulsive therapy compared with magnetic seizure therapy for treatment-resistant depression. British Journal of Anaesthesia, 112(4), 695–702. https://doi.org/10.1093/bja/aet410

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free