Visual detection of cortical breaks in hand joints: Reliability and validity of high-resolution peripheral quantitative CT compared to microCT

13Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To study the reliability and validity of high-resolution peripheral quantitative CT (HR-pQCT) with microCT (μCT) as gold standard in the visual detection of cortical breaks in metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints. Methods: Ten cadaveric fingers (10 MCP and 9 PIP joints) were imaged by HR-pQCT and μCT and visually analyzed by two independent readers. Intra- and interreader reliability were evaluated for the presence (yes/no, kappa statistics) and the total number (intraclass correlation coefficient, ICC) of cortical breaks. Sensitivity, specificity, positive and negative predictive value (PPV respectively NPV) of HR-pQCT in detecting cortical breaks were calculated. Results: With HR-pQCT, mean 149 cortical breaks were identified and with μCT mean 129 (p < 0.05). Intrareader reliability for the presence of a cortical break per quadrant was 0.52 (95 % CI 0.48-0.56) and 0.71 (95 % CI 0.67-0.75) for HR-pQCT and μCT, respectively, and for the total number of cortical breaks 0.61 (95 % CI 0.49-0.70) and 0.75 (95 % CI 0.68-0.82). Interreader reliability for the presence of a cortical break per quadrant was 0.37 (95 % CI 0.33-0.41) and 0.45 (95 % CI 0.41-0.49) for HR-pQCT and μCT, respectively, and for the number of cortical breaks 0.55 (95 % CI 0.43-0.65) and 0.54 (95 % CI 0.35-0.67). Sensitivity, specificity, PPV and NPV of HR-pQCT were 81.6, 64.0, 81.6, and 64 % respectively. Conclusion: Cortical breaks were commonly visualized in MCP and PIP joints with HR-pQCT and μCT. Reliability of both HR-pQCT and μCT was fair to moderate. HR-pQCT was highly sensitive to detect cortical breaks with μCT as gold standard.

Cite

CITATION STYLE

APA

Scharmga, A., Peters, M., Van Tubergen, A., Van Den Bergh, J., De Jong, J., Loeffen, D., … Geusens, P. (2016). Visual detection of cortical breaks in hand joints: Reliability and validity of high-resolution peripheral quantitative CT compared to microCT. BMC Musculoskeletal Disorders, 17(1). https://doi.org/10.1186/s12891-016-1148-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free