Oxygenation performance assessment of an artificial lung in different central anatomic configurations

1Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: Aim of this work was to characterize possible central anatomical configurations in which a future artificial lung (AL) could be connected, in terms of oxygenation performance. Methods: Pulmonary and systemic circulations were simulated using a numerical and an in vitro approach. The in vitro simulation was carried out in a mock loop in three phases: (1) normal lung, (2) pulmonary shunt (50% and 100%), and (3) oxygenator support in three anatomical configurations: right atrium-pulmonary artery (RA-PA), pulmonary artery-left atrium (PA-LA), and aorta-left atrium (Ao-LA). The numerical simulation was performed for the oxygenator support phase. The oxygen saturation (SO2) of the arterial blood was plotted over time for two percentages of pulmonary shunt and three blood flow rates through the oxygenator. Results: During the pulmonary shunt phase, SO2 reached a steady state value (of 68% for a 50% shunt and of nearly 0% for a 100% shunt) 20 min after the shunt was set. During the oxygenator support phase, physiological values of SO2 were reached for RA-PA and PA-LA, in case of a 50% pulmonary shunt. For the same conditions, Ao-LA could reach a maximum SO2 of nearly 60%. Numerical results were congruous to the in vitro simulation ones. Conclusions: Both in vitro and numerical simulations were able to properly characterize oxygenation properties of a future AL depending on its placement. Different anatomical configurations perform differently in terms of oxygenation. Right to right and right to left connections perform better than left to left ones.

References Powered by Scopus

Left Ventricular Unloading Is Associated With Lower Mortality in Patients With Cardiogenic Shock Treated With Venoarterial Extracorporeal Membrane Oxygenation Results From an International, Multicenter Cohort Study

362Citations
N/AReaders
Get full text

Cannulation strategies for percutaneous extracorporeal membrane oxygenation in adults

207Citations
N/AReaders
Get full text

Intensive care, right ventricular support and lung transplantation in patients with pulmonary hypertension

153Citations
N/AReaders
Get full text

Cited by Powered by Scopus

In vitro evaluation of the performance of an oxygenator depending on the non-standard gas content of the inlet blood with special regard on CO2 elimination

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Hima, F., Kalverkamp, S., Kashefi, A., Mottaghy, K., Zayat, R., Strudthoff, L., … Mouzakis, F. (2023). Oxygenation performance assessment of an artificial lung in different central anatomic configurations. International Journal of Artificial Organs, 46(5), 295–302. https://doi.org/10.1177/03913988231168163

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

100%

Readers' Discipline

Tooltip

Medicine and Dentistry 1

50%

Pharmacology, Toxicology and Pharmaceut... 1

50%

Save time finding and organizing research with Mendeley

Sign up for free