Canine model of esophageal injury and atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound and side-firing unfocused ultrasound in the left atrium and inside the pulmonary vein

65Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

Abstract

Background-Left atrial- esophageal fistula is a serious and poorly understood complication of catheter ablation of atrial fibrillation. The purpose of this study was to (1) develop a canine model of esophageal injury and left atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound (HIFU) and side-firing unfocused ultrasound (SFU); (2) examine the relationship to esophageal temperature (Eso-temp); and (3) study the evolution of injury/healing. Methods and Results-Twenty dogs were studied. After transeptal puncture, HIFU catheter (ProRhythm Inc; 13 dogs) was positioned close to the esophagus, either outside (n=6) or inside (n=7) the inferior pulmonary vein (PV). In 7 other dogs, an SFU catheter was placed deep inside the PV, close to the esophagus. A balloon (20- to 25-mm diameter) with 7 thermocouples (2-mm separation) was positioned in the esophagus (Eso-balloon). Variable air filling of the Eso-balloon controlled the distance from the esophagus to the sonication source, pressing the esophagus against left atrium/PV. One to 9 (median, 5) HIFU (35 W) and 5 to 7 (median, 5) SFU (40 W) sonications were delivered for 40 seconds. Maximum luminal Eso-temp was closely related to HIFU Eso-balloon distance. For HIFU outside PV, Eso-temp ≥50°C occurred only for HIFU Eso-balloon distance ≤2 mm. For HIFU/SFU inside the PV, Eso-temp was ≥50°C, with HIFU Eso-balloon distance up to 6.8 mm. Endoscopy identified esophageal ulcer immediately after ablation in 11 of 13 HIFU dogs and 7 of 7 SFU dogs, all with Eso-temp ≥50°C. Endoscopy at 2 weeks showed ulcer healing in 5 of 11 chronic dogs and ulcer size progression with relaxation of the lower esophageal sphincter and esophagitis in 6 dogs. Two dogs developed left atrial-esophageal fistula and died at 2 weeks. Conclusions-This model produces esophageal ulcer when Eso-temp is ≥50°C. Eso-temp is higher with HIFU/SFU applications closer to the esophagus and with HIFU/SFU applications inside the PV. Ulcer progression and left atrial-esophageal fistula were associated with reflux esophagitis. (Circ Arrhythmia Electrophysiol. 2009;2:41-49.) © 2009 American Heart Association, Inc.

Cite

CITATION STYLE

APA

Yokoyama, K., Nakagawa, H., Seres, K. A., Jung, E., Merino, J., Zou, Y., … Jackman, W. M. (2009). Canine model of esophageal injury and atrial-esophageal fistula after applications of forward-firing high-intensity focused ultrasound and side-firing unfocused ultrasound in the left atrium and inside the pulmonary vein. Circulation: Arrhythmia and Electrophysiology, 2(1), 41–49. https://doi.org/10.1161/CIRCEP.108.807925

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free