Higher cut-off values of non-invasive methods might be needed to detect moderate-to-severe steatosis in morbid obese patients: a pilot study

4Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

To evaluate the diagnostic value of described thresholds of controlled attenuation parameter (CAP) and biomarker scores for liver steatosis and to evaluate new cut-offs to detect moderate-to-severe steatosis (S2–3) in patients with morbid obesity. In this prospective study, 32 patients with morbid obesity with indications for bariatric surgery (15 women and 17 men, mean age = 36 years, median BMI = 40.2 kg/m2) underwent CAP, magnetic resonance spectroscopy (MRS), three biomarker scores (Steato-ELSA, Fatty Liver Index (FLI), and Hepatic Steatosis Index (HSI)), and liver biopsy. Subjects were divided into an exploratory cohort (reliable CAP and liver biopsy) and a confirmatory cohort (reliable CAP and MRS) to evaluate new thresholds for CAP and biomarker scores to detect S2–3. Receiver operator characteristic (ROC) curves analyses were performed and the optimal cut-off points were identified using the maximal Youden index. A total of 22 patients had CAP measure and liver biopsy (exploratory cohort) and 24 patients had CAP measure with MRS (confirmatory cohort). New cut-offs were identified for detection of S2–3 by the non-invasive tests using liver biopsy as the reference standard (exploratory cohort). Considering the new proposed cut-offs for detection of S2–3 for CAP (≥ 314 dB/m), Steato-ELSA (≥ 0.832), FLI (≥ 96), and HSI (≥ 53), for the exploratory and confirmatory cohorts sensitivities were: 71–75%, 86–81%, 85–81%, and 71–69% and specificities were: 94–89%, 75–63%, 63–63%, and 75–88%, respectively. Higher cut-offs for CAP and biomarker scores may be better to diagnose moderate-to-severe steatosis in patients with morbid obesity.

Cite

CITATION STYLE

APA

Parente, D. B., Perazzo, H., Paiva, F. F., Campos, C. F. F., Saboya, C. J., Pereira, S. E., … Perez, R. de M. (2020). Higher cut-off values of non-invasive methods might be needed to detect moderate-to-severe steatosis in morbid obese patients: a pilot study. Scientific Reports, 10(1). https://doi.org/10.1038/s41598-020-71723-2

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free