On the estimation of transmural myocardial shear by means of MRI tagging

3Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The reliability of non-invasive myocardial shear measurements based on MRI tagging is evaluated in relation to the influence of possible edge effects close to myocardial borders. Automatic cardiac motion tracking is performed with SinMod, a method based on sinusoidal wave modeling. Shear results are evaluated for simulated images with a known imposed motion field, as well as for real short-axis acquisitions from 10 healthy volunteers. To evaluate accuracy and precision in vivo, automatic results are compared with manual tracings. Results show that estimation of circumferential-radial shear is feasible in vivo, where edge effects close to myocardial borders play a minor role as compared with those found in synthetic images. In healthy subjects, circumferential-radial shear and rotation of the myocardium appear negatively correlated. © 2011 Springer-Verlag Berlin Heidelberg.

Cite

CITATION STYLE

APA

Rossi, A. C., Arts, T., & Delhaas, T. (2011). On the estimation of transmural myocardial shear by means of MRI tagging. In Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) (Vol. 6666 LNCS, pp. 105–112). https://doi.org/10.1007/978-3-642-21028-0_13