A magnetic solid phase extraction technique followed by liquid chromatography with a fluorescence detector for naproxen analysis in human urine samples was developed. The method includes the extraction of naproxen with a magnetic solid synthetized with magnetite and poly 4-vinylpriridine, followed by the magnetic separation of the solid phase and desorption of the analyte with methanol. Under optimal conditions, the linear range of the calibration curve was 0.05–0.60 µg L-1, with a limit of detection of 0.02 µg L-1. In all cases values of repeatability were lower than 5.0% with recoveries of 99.4 ± 1.3%. Precision and accuracy values are adequate for naproxen (Npx) analysis in urine samples.
CITATION STYLE
Escamilla-Lara, K. A., Heredia, A. C., Peña-Alvarez, A., Ibarra, I. S., Barrado, E., & Rodriguez, J. A. (2020). Magnetic solid-phase extraction based on poly 4-vinyl pyridine for HPLC-FLD analysis of naproxen in urine samples. Molecules, 25(12). https://doi.org/10.3390/molecules25122924