Abstract

High-rise buildings are subjected during severe earthquakes and strong winds to intensive large axial and lateral loads, particularly at their lower stories, where the exterior columns experience varying high axial loads. Herein, the seismic performance of two precast high-strength reinforced concrete exterior beam-column joints subjected to different varying high-axial levels is investigated while premature shear failure is generally suspected. High-grade steel bars were used for reinforcement. Splice grout-sleeves and mechanical anchors were used in the columns and beams, respectively. The strength of the concrete was 70 MPa. The maximum axial tension level in columns was 90% of the yield strength of the main bars. Under high axial tension, the tested subassemblies exhibited stable response, good damping characteristics, appropriate lateral force resistance and energy absorption capacity. They performed well within the lateral story drift angle of 3% where the successive failure modes (beam/column flexural yielding followed by joint shear failure) confirmed the appropriateness of the design equations in AIJ and ACI regulations. Furthermore, the use of mechanical anchors proved to be very effective and no sign of concrete crushing (pushing toward the exterior face of the joint) was observed within the lateral story drift angle of 2%. Copyright © 2009 Japan Concrete Institute.

References Powered by Scopus

Requirements for the use of PRESSS moment-resisting frame systems

15Citations
N/AReaders
Get full text

Codification of PRESS structural systems

8Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Experimental study on mechanical behavior of thermally damaged grouted sleeve splice under cyclic loading

21Citations
N/AReaders
Get full text

The effect of compressed infill panels on cyclic performance of exterior beam-column joints

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ousalem, H., Takatsu, H., Ishikawa, Y., & Kimura, H. (2009). Seismic testing and performance of precast high-strength concrete beam-column joints subjected to high axial tension. Journal of Advanced Concrete Technology, 7(2), 195–204. https://doi.org/10.3151/jact.7.195

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 7

88%

Lecturer / Post doc 1

13%

Readers' Discipline

Tooltip

Engineering 9

100%

Save time finding and organizing research with Mendeley

Sign up for free