Water distribution networks face several problems related to leakages, where the pressure control strategy is a common practice for water loss management. Small-scale hydropower schemes, where pumps as turbines replace pressure reducing valves, can be considered an interesting technical solution, which ensures both economic convenience and system flexibility. Due to the water networks' variable operating conditions, a new methodology to model the effectiveness of pumps as turbines was developed based on the efficiency and the mechanical reliability of the hydropower device and the flexibility of the plant. System effectiveness is proposed as the objective function in the optimization procedure and applied to a real system, enabling one to emphasize that the hydraulic regulation mode of the plant is better than the electric regulation mode for American Petroleum Industry (API) manufacturing standards of pumps. © 2013 by the authors.

Cite

CITATION STYLE

APA

Carravetta, A., Del Giudice, G., Fecarotta, O., & Ramos, H. M. (2013). Pump as turbine (PAT) design in water distribution network by system effectiveness. Water (Switzerland), 5(3), 1211–1225. https://doi.org/10.3390/w5031211