Abstract

Modern fluoroscopes used for image-based guidance in interventional procedures are complex X-ray machines, with advanced image acquisition and processing systems capable of automatically controlling numerous parameters based on defined protocol settings. This study evaluated and compared approaches to technique factor modulation and air kerma rates in response to simulated patient thickness variations for four state-of-the-art and one previous-generation interventional fluoroscopes. A polymethyl methacrylate (PMMA) phantom was used as a tissue surrogate for the purposes of determining fluoroscopic reference plane air kerma rates, kVp, mA, and variable copper filter thickness over a wide range of simulated tissue thicknesses. Data were acquired for each fluoroscopic and acquisition dose curve within each vendor's default abdomen or body imaging protocol. The data obtained indicated vendor- and model-specific variations in the approach to tech-nique factor modulation and reference plane air kerma rates across a range of tissue thicknesses. However, in the imaging protocol evaluated, all of the state-of-the-art systems had relatively low air kerma rates in the fluoroscopic low-dose imaging mode as compared to the previous-generation unit. Each of the newest-generation systems also employ Cu filtration within the selected protocol in the acquisition mode of imaging; this is a substantial benefit, reducing the skin entrance dose to the patient in the highest dose-rate mode of fluoroscope operation. Some vendors have also enhanced the radiation output capabilities of their fluoroscopes which, under specific conditions, may be beneficial; however, these increased output capabilities also have the potential to lead to unnecessarily high dose rates. Understanding how fluoroscopic technique factors are modulated provides insight into the vendor-specific image acquisition approach and may provide opportunities to optimize the imaging protocols for clinical practice.

Author supplied keywords

References Powered by Scopus

Overview of contemporary interventional fluoroscopy procedures

90Citations
N/AReaders
Get full text

The operation logic of automatic dose control of fluoroscopy system in conjunction with spectral shaping filters

46Citations
N/AReaders
Get full text

SU‐GG‐I‐96: The “30‐30‐30 Rule”, a Practical Guide to Setting the Detector Input Exposure Rate for a Fluoroscopic Imager

3Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Implementation of a spatio-temporal figure of merit for new automatic dose rate control regimes in dynamic x-ray imaging

16Citations
N/AReaders
Get full text

Velopharyngeal videofluoroscopy: Providing useful clinical information in the era of reduced dose radiation and safety

15Citations
N/AReaders
Get full text

Occupational and patient radiation doses in a modern cardiac electrophysiology laboratory

10Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Wunderle, K. A., Rakowski, J. T., & Dong, F. F. (2016). Approaches to interventional fluoroscopic dose curves. Journal of Applied Clinical Medical Physics, 17(1), 342–352. https://doi.org/10.1120/jacmp.v17i1.5788

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

57%

Researcher 3

21%

Lecturer / Post doc 2

14%

Professor / Associate Prof. 1

7%

Readers' Discipline

Tooltip

Physics and Astronomy 10

53%

Medicine and Dentistry 6

32%

Nursing and Health Professions 2

11%

Engineering 1

5%

Save time finding and organizing research with Mendeley

Sign up for free