Fifteen years of external quality assessment in leukemia/lymphoma immunophenotyping in the Netherlands and Belgium: A way forward

9Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In 1985, external quality assurance was initiated in the Netherlands to reduce the between-laboratory variability of leukemia/lymphoma immunophenotyping and to improve diagnostic conclusions. This program consisted of regular distributions of test samples followed by biannual plenary participant meetings in which results were presented and discussed. A scoring system was developed in which the quality of results was rated by systematically reviewing the pre-analytical, analytical, and post-analytical assay stages using three scores, i.e., correct (A), minor fault (B), and major fault (C). Here, we report on 90 consecutive samples distributed to 40-61 participating laboratories between 1998 and 2012. Most samples contained >20% aberrant cells, mainly selected from mature lymphoid malignancies (B or T cell) and acute leukemias (myeloid or lymphoblastic). In 2002, minimally required monoclonal antibody (mAb) panels were introduced, whilst methodological guidelines for all three assay stages were implemented. Retrospectively, we divided the study into subsequent periods of 4 ("initial"), 4 ("learning"), and 7 years ("consolidation") to detect "learning effects." Uni- and multivariate models showed that analytical performance declined since 2002, but that post-analytical performance improved during the entire period. These results emphasized the need to improve technical aspects of the assay, and reflected improved interpretational skills of the participants. A strong effect of participant affiliation in all three assay stages was observed: laboratories in academic and large peripheral hospitals performed significantly better than those in small hospitals.

Cite

CITATION STYLE

APA

Preijers, F. W. M. B., Van Der Velden, V. H. J., Preijers, T., Brooimans, R. A., Marijt, E., Homburg, C., … Gratama, J. W. (2016). Fifteen years of external quality assessment in leukemia/lymphoma immunophenotyping in the Netherlands and Belgium: A way forward. Cytometry Part B - Clinical Cytometry, 90(3), 267–278. https://doi.org/10.1002/cyto.b.21266

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free