Finite element analysis of Novel separable fixture for easy retrievement in case with peri-implantitis

18Citations
Citations of this article
36Readers
Mendeley users who have this article in their library.

Abstract

Peri-implantitis is a common complication following dental implant placement, which may lead to bone loss and fixation failure. With the conventional fixture, it is difficult to perfectly clear-up the infection. To solve this, we have designed a separable fixture of which the top part is replaceable. This study aimed to compare the structural and biomechanical stability of the separable and conventional fixture. A single surgical model corresponding to the first molar in a virtual mandible model and conventional/separable implants were reproduced to compare the biomechanical characteristics of the implants using finite element analysis (FEA). The loading condition was 200N preload in the first step, and 100N (Axial), 100N (15°), and 30N (45°) in the second step. The stress distribution on the cortical bone in the separable implant was lower than the conventional implant. In particular, the Peak von Mises Stress (PVMS) values of the separable implant under lateral load was found to be about twice as low as that of the conventional implant. In this study, we suggest that the separable implant has an equivalent biomechanical stability compared to the conventional implant, is easy to retrieve in the case of peri-implantitis, and has an excellent initial stability after the surgery when used in stage 2.

References Powered by Scopus

Biomedical applications of titanium and its alloys

836Citations
N/AReaders
Get full text

Application of finite element analysis in implant dentistry: A review of the literature

824Citations
N/AReaders
Get full text

A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years: I. Implant-supported FPDs

519Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Sandblasted and acid etched titanium dental implant surfaces systematic review and confocal microscopy evaluation

69Citations
N/AReaders
Get full text

Efficient design of a clear aligner attachment to induce bodily tooth movement in orthodontic treatment using finite element analysis

45Citations
N/AReaders
Get full text

Failure analysis of a humeral shaft locking compression plate-surface investigation and simulation by finite element method

45Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kim, W. H., Song, E. S., Ju, K. W., Lee, J. H., Kim, M. Y., Lim, D., & Kim, B. (2019). Finite element analysis of Novel separable fixture for easy retrievement in case with peri-implantitis. Materials, 12(2). https://doi.org/10.3390/ma12020235

Readers over time

‘19‘20‘21‘22‘23‘240481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 11

69%

Researcher 3

19%

Lecturer / Post doc 2

13%

Readers' Discipline

Tooltip

Engineering 9

45%

Medicine and Dentistry 9

45%

Materials Science 1

5%

Computer Science 1

5%

Save time finding and organizing research with Mendeley

Sign up for free
0