Body water distribution in severe obesity and its assessment from eight-polar bioelectrical impedance analysis

130Citations
Citations of this article
126Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To measure body water distribution and to evaluate the accuracy of eight-polar bioelectrical impedance analysis (BIA) for the assessment of total body water (TBW) and extracellular water (ECW) in severe obesity. Design: Cross-sectional study. Setting: Obesity clinic. Subjects: In all, 75 women aged 18-66y, 25 with body mass index (BMI) between 19.1 and 29.9 kg/m2 (ie not obese), 25 with BMI between 30.0 and 39.9 kg/m2 (ie class I and II obese), and 25 with BMI between 40.0 and 48.2 kg/m2 (ie class III obese). Methods: TBW and ECW were measured by 2H20 and Br dilution. Body resistance (R) was obtained by summing the resistances of arms, trunk and legs as measured by eight-polar BIA (InBody 3.0, Biospace, Seoul, Korea). The resistance index at a frequency of x kHz (RIx) was calculated as height 2/Rx. Results: ECW : TBW was similar in women with class III (46 ± 3%, mean ± s.d.) and class I-II obesity (45 ± 3%) but higher than in nonobese women (39 ± 3%, P<0.05). In a random subsample of 37 subjects, RI500 explained 82% of TBW variance (P<0.0001) and cross-validation of the obtained algorithm in the remaining 38 subjects gave a percent root mean square error (RMSE%) of 5% and a pure error (PE) of 2.11. In the same subjects, RIs explained 87% of ECW variance (P<0.0001) and cross-validation of the obtained algorithm gave a RMSE% of 8% and a PE of 1.4 I. The contribution of weight and BMI to the prediction of TBW and ECW was nil or negligible on practical grounds. Conclusions: ECW : TBW is similar in women with class I-II and class III obesity up to BMI values of 48.2 kg/m2. Eight-polar BIA offers accurate estimates of TBW and ECW in women with a wide range of BMI (19.1-48.2 kg/m2) without the need of population-specific formulae. © 2005 Nature Publishing Group. All rights reserved.

Cite

CITATION STYLE

APA

Sartorio, A., Malavolti, M., Agosti, F., Marinone, P. G., Caiti, O., Battistini, N., & Bedogni, G. (2005). Body water distribution in severe obesity and its assessment from eight-polar bioelectrical impedance analysis. European Journal of Clinical Nutrition, 59(2), 155–160. https://doi.org/10.1038/sj.ejcn.1602049

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free