Accuracy of digital implant impressions obtained using intraoral scanners: a systematic review and meta-analysis of in vivo studies

  • Ma J
  • Zhang B
  • Song H
  • et al.
N/ACitations
Citations of this article
42Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

PURPOSE This systematic review aimed to investigate the accuracy of intraoral scan (IOS) impressions of implant-supported restorations in in vivo studies. METHODS A systematic electronic search and review of studies on the accuracy of IOS implant impressions were conducted to analyze the peer-reviewed literature published between 1989 and August 2023. The bias analysis was performed by two reviewers. Data on the study characteristics, accuracy outcomes, and related variables were extracted. A meta-analysis of randomized control trials was performed to investigate the impact of IOS on peri-implant crestal bone loss and the time involved in the impression procedure. RESULTS Ten in vivo studies were included in this systematic review for final analysis. Six studies investigated the trueness of IOS impressions, but did not reach the same conclusions. One study assessed the precision of IOS impressions for a single implant. Four clinical studies examined the accuracy of IOS implant impressions with a follow-up of 1-2 years. In full arches, IOS impression procedure needed significantly less time than conventional one (mean difference for procedure time was 8.59 min [6.78, 10.40 min], P < 0.001), prosthetic survival rate was 100%, and marginal bone levels of all participants could be stably maintained (mean difference in marginal bone loss at 12 months was 0.03 mm [-0.08, 0.14 mm], P = 0.55). CONCLUSIONS The accuracy of IOS impressions of implant-supported restorations varied greatly depending on the scanning strategy. The trueness and precision of IOS in the partial and complete arches remain unclear and require further assessment. Based on follow-up clinical studies, IOS impressions were accurate in clinical practice. However, these results should be interpreted with caution, as some evidences are obtained from the same research group.

Cite

CITATION STYLE

APA

Ma, J., Zhang, B., Song, H., Wu, D., & Song, T. (2023). Accuracy of digital implant impressions obtained using intraoral scanners: a systematic review and meta-analysis of in vivo studies. International Journal of Implant Dentistry, 9(1). https://doi.org/10.1186/s40729-023-00517-8

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free