Quality improvement process to assess tattoo alignment, set-up accuracy and isocentre reproducibility in pelvic radiotherapy patients

5Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

Introduction: This quality improvement study tested three methods of tattoo alignment and isocentre definition to investigate if aligning lateral tattoos to minimise pitch, roll and yaw decreased set-up error, and if defining the isocentre using the lateral tattoos for cranio-caudal (CC) position improved isocentre reproducibility. The study population was patients receiving curative external beam radiotherapy (EBRT) for prostate cancer. The results are applicable to all supine pelvic EBRT patients. Methods: The three sequential cohorts recruited 11, 11 and 10 patients respectively. A data set of 20 orthogonal pairs of electronic portal images (EPI) was acquired for each patient. EPIs were matched offline to digitally reconstructed radiographs. In cohort 1, lateral tattoos were adjusted to minimise roll. The anterior tattoo was used to define the isocentre. In cohort 2, lateral tattoos were aligned to minimise roll and yaw. Isocentre was defined as per cohort 1. In cohort 3, lateral tattoos were aligned as per cohort 2 and the anterior tattoo was adjusted to minimise pitch. Isocentre was defined by the lateral tattoos for CC position and the anterior tattoo for the left-right position. Results: Cohort 3 results were superior as CC systematic and random set-up errors reduced from -1.3 mm to -0.5 mm, and 3.1 mm to 1.4 mm respectively, from cohort 1 to cohort 3. Isocentre reproducibility also improved from 86.7% to 92.1% of treatment isocentres within 5 mm of the planned isocentre. Conclusion: The methods of tattoo alignment and isocentre definition in cohort 3 reduced set-up errors and improved isocentre reproducibility. A prospective three cohort quality improvement study to improve set-up accuracy for patients receiving pelvic radiotherapy without intraprostatic fiducial markers. Alignment of tattoos to minimise roll, yaw and pitch and defining cranio-caudal (CC) isocentre position at the lateral tattoos improved set-up accuracy and isocentre reproducibility.

Author supplied keywords

References Powered by Scopus

Errors and Margins in Radiotherapy

1222Citations
N/AReaders
Get full text

Set-up verification using portal imaging; review of current clinical practice

329Citations
N/AReaders
Get full text

Rectal and urinary dysfunction in the TROG 03.04 RADAR trial for locally advanced prostate cancer

38Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Comparison of initial patient setup accuracy between surface imaging and three point localization: A retrospective analysis

83Citations
N/AReaders
Get full text

Augmented reality-guided positioning system for radiotherapy patients

15Citations
N/AReaders
Get full text

Learning healthcare systems and rapid learning in radiation oncology: Where are we and where are we going?

14Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Elsner, K., Francis, K., Hruby, G., & Roderick, S. (2014). Quality improvement process to assess tattoo alignment, set-up accuracy and isocentre reproducibility in pelvic radiotherapy patients. Journal of Medical Radiation Sciences, 61(4), 246–252. https://doi.org/10.1002/jmrs.79

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 11

79%

Researcher 2

14%

Professor / Associate Prof. 1

7%

Readers' Discipline

Tooltip

Medicine and Dentistry 6

38%

Physics and Astronomy 5

31%

Nursing and Health Professions 4

25%

Engineering 1

6%

Save time finding and organizing research with Mendeley

Sign up for free