Single parameter fault identification technique for DC motor through wavelet analysis and fuzzy logic

10Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

Abstract

DC motors are widely used in industries like cement, paper manufacturing, etc., even today. Early fault identification in dc motors significantly improves its life time and reduces power consumption. Many conventional and soft computing techniques for fault identification in DC motors including a recent work using model based analysis with the help of fuzzy logic are available in literature. In this paper fuzzy logic and norm based wavelet analysis of startup transient current are proposed to identify and quantify the armature winding fault and bearing fault in DC motors, respectively. Results obtained by simulation using Matlab and Simulink are presented in this paper to validate the proposed work.

Cite

CITATION STYLE

APA

Winston, D. P., & Saravanan, M. (2013). Single parameter fault identification technique for DC motor through wavelet analysis and fuzzy logic. Journal of Electrical Engineering and Technology, 8(5), 1049–1055. https://doi.org/10.5370/JEET.2013.8.5.1049

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free