Effect of collimator and couch angle change on breast IMRT dose distributions

1Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Intensity-modulated tangential photon beams for breast cancer treatment can improve the dose uniformity significantly throughout the whole breast and reduce the dose to the lung and the heart when compared to the conventional technique. Before the first treatment, patient setup may require a change on the collimator angle and/or the couch angle based on the chest wall coverage according to the port films. The objective of this work is to investigate the effects of the collimator and the couch angle change on the dose distribution for breast cancer treatment using intensity-modulated tangential photon beams, and to determine the clinical acceptable range of the angle change for routine treatment. Ten breast cases treated with intensity-modulated tangential photon beams were analyzed in this study. Patient- specific CT data and the radiation therapy planning (RTP) files obtained from our in-house Monte Carlo based breast IMRT treatment planning system were used for IMRT dose recalculation with collimator or couch angle changes. The isodose distributions and DVHs were compared with the original plans, and the effects of the collimator and couch angle change to breast IMRT dose distributions were evaluated. Our results show that a 4° change in the collimator angle or the couch angle did not affect the dose distribution significantly and it is acceptable in the clinic for patient treatment.

References Powered by Scopus

Eight-Year Results of a Randomized Clinical Trial Comparing Total Mastectomy and Lumpectomy with or without Irradiation in the Treatment of Breast Cancer

1545Citations
N/AReaders
Get full text

A comparison of different intensity modulation treatment techniques for tangential breast irradiation

100Citations
N/AReaders
Get full text

A simplified intensity modulated radiation therapy technique for the breast

90Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Analysis of Influence of Errors in Angular Settings of Couch and Collimator on the Dosimetric and Radiobiological Parameters in VMAT Plans

2Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yang, J., Ma, C., Wang, L., Chen, L., & Li, J. (2009). Effect of collimator and couch angle change on breast IMRT dose distributions. Journal of Applied Clinical Medical Physics, 10(4), 55–63. https://doi.org/10.1120/jacmp.v10i4.3058

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

57%

Professor / Associate Prof. 2

29%

Researcher 1

14%

Readers' Discipline

Tooltip

Physics and Astronomy 6

67%

Medicine and Dentistry 2

22%

Nursing and Health Professions 1

11%

Save time finding and organizing research with Mendeley

Sign up for free