Linearly chirped fiber Bragg grating response to thermal gradient: from bench tests to the real-time assessment during in vivo laser ablations of biological tissue

  • Saccomandi P
  • Varalda A
  • Gassino R
  • et al.
35Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

Abstract

© 2017 Society of Photo-Optical Instrumentation Engineers (SPIE). The response of a fiber optic sensor [linearly chirped fiber Bragg grating (LCFBG)] to a linear thermal gradient applied on its sensing length (i.e., 1.5 cm) has been investigated. After these bench tests, we assessed their feasibility for temperature monitoring during thermal tumor treatment. In particular, we performed experiments during ex vivo laser ablation (LA) in pig liver and in vivo thermal ablation in animal models (pigs). We investigated the following: (i) the relationship between the full width at half maximum of the LCFBG spectrum and the temperature difference among the extremities of the LCFBG and (ii) the relationship between the mean spectrum wavelength and the mean temperature acting on the LCFBG sensing area. These relationships showed a linear trend during both bench tests and LA in animal models. Thermal sensitivity was significant although different values were found with regards to bench tests and animal experiments. The linear trend and significant sensitivity allow hypothesizing a future use of this kind of sensor to monitor both temperature gradient and mean temperature within a tissue undergoing thermal treatment.

References Powered by Scopus

Fiber grating sensors

4126Citations
N/AReaders
Get full text

Fiber Bragg grating technology fundamentals and overview

2946Citations
N/AReaders
Get full text

Recent Progress in Distributed Fiber Optic Sensors

1246Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Review of chirped fiber bragg grating (CFBG) fiber-optic sensors and their applications

140Citations
N/AReaders
Get full text

Fiber optic sensors for sub-centimeter spatially resolved measurements: Review and biomedical applications

139Citations
N/AReaders
Get full text

Analysis and Design of Chirped Fiber Bragg Grating for Temperature Sensing for Possible Biomedical Applications

54Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Saccomandi, P., Varalda, A., Gassino, R., Tosi, D., Massaroni, C., Caponero, M. A., … Schena, E. (2017). Linearly chirped fiber Bragg grating response to thermal gradient: from bench tests to the real-time assessment during in vivo laser ablations of biological tissue. Journal of Biomedical Optics, 22(09), 1. https://doi.org/10.1117/1.jbo.22.9.097002

Readers over time

‘17‘18‘19‘20‘21‘22‘23‘240481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 14

64%

Researcher 6

27%

Professor / Associate Prof. 2

9%

Readers' Discipline

Tooltip

Engineering 19

86%

Chemical Engineering 1

5%

Social Sciences 1

5%

Physics and Astronomy 1

5%

Save time finding and organizing research with Mendeley

Sign up for free
0