Accelerometer-based method for correcting signal baseline changes caused by motion artifacts in medical near-infrared spectroscopy

  • Virtanen J
  • Noponen T
  • Kotilahti K
  • et al.
81Citations
Citations of this article
108Readers
Mendeley users who have this article in their library.

Abstract

In medical near-infrared spectroscopy (NIRS), movements of the subject often cause large step changes in the baselines of the measured light attenuation signals. This prevents comparison of hemoglobin concentration levels before and after movement. We present an accelerometer-based motion artifact removal (ABAMAR) algorithm for correcting such baseline motion artifacts (BMAs). ABAMAR can be easily adapted to various long-term monitoring applications of NIRS. We applied ABAMAR to NIRS data collected in 23 all-night sleep measurements and containing BMAs from involuntary movements during sleep. For reference, three NIRS researchers independently identified BMAs from the data. To determine whether the use of an accelerometer improves BMA detection accuracy, we compared ABAMAR to motion detection based on peaks in the moving standard deviation (SD) of NIRS data. The number of BMAs identified by ABAMAR was similar to the number detected by the humans, and 79 of the artifacts identified by ABAMAR were confirmed by at least two humans. While the moving SD of NIRS data could also be used for motion detection, on average 2 out of the 10 largest SD peaks in NIRS data each night occurred without the presence of movement. Thus, using an accelerometer improves BMA detection accuracy in NIRS. © 2011 Society of Photo-Optical Instrumentation Engineers (SPIE).

References Powered by Scopus

Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters

3321Citations
N/AReaders
Get full text

HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain

1261Citations
N/AReaders
Get full text

The visual scoring of sleep in adults

810Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Motion artifacts in functional near-infrared spectroscopy: A comparison of motion correction techniques applied to real cognitive data

428Citations
N/AReaders
Get full text

Statistical analysis of fNIRS data: A comprehensive review

349Citations
N/AReaders
Get full text

A systematic comparison of motion artifact correction techniques for functional near-infrared spectroscopy

334Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Virtanen, J., Noponen, T., Kotilahti, K., Virtanen, J., & Ilmoniemi, R. J. (2011). Accelerometer-based method for correcting signal baseline changes caused by motion artifacts in medical near-infrared spectroscopy. Journal of Biomedical Optics, 16(8), 087005. https://doi.org/10.1117/1.3606576

Readers over time

‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘2505101520

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 48

71%

Researcher 13

19%

Professor / Associate Prof. 6

9%

Lecturer / Post doc 1

1%

Readers' Discipline

Tooltip

Engineering 30

60%

Medicine and Dentistry 7

14%

Psychology 7

14%

Neuroscience 6

12%

Save time finding and organizing research with Mendeley

Sign up for free
0