Designing a Novel Porous Fixation Plate with a Gyroid Lattice Structure for Humerus Fractures Using a Probabilistic Approach

0Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Conventional fixation plates permanently attached to the body can lead to complications, such as stress shielding and aseptic loosening, due to their contact with the bone, resulting in bone loss. The contact between these solid fixation plates and the bone surface inhibits blood flow, potentially leading to necrosis at the interface. To overcome this challenge, a porous implant featuring a gyroid lattice structure for humerus bone fixation is proposed. However, designing such an implant typically involves deterministic approaches, which do not account for uncertainties in design parameters, loadings on the plate, and additive manufacturing process parameters. Consequently, the actual conditions experienced by the plate may not be accurately modeled. Herein, both deterministic and probabilistic analyses of a porous implant with a gyroid lattice structure positioned on the humeral bone is conducted. The findings are compared to the failure probabilities of both the conventional fixation plate and the optimal plate derived from a previous study. The study reveals that uncertainties in design parameters significantly influence the plate's failure probability compared to deterministic analysis, emphasizing the importance of probability-based analyses for a reliable plate design.

References Powered by Scopus

Topological design and additive manufacturing of porous metals for bone scaffolds and orthopaedic implants: A review

1735Citations
N/AReaders
Get full text

Ti-6Al-4V triply periodic minimal surface structures for bone implants fabricated via selective laser melting

577Citations
N/AReaders
Get full text

Role of pore size and morphology in musculo-skeletal tissue regeneration

381Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kaymaz, I., Yavuz, O., Murat, F., & Korkmaz, İ. H. (2024). Designing a Novel Porous Fixation Plate with a Gyroid Lattice Structure for Humerus Fractures Using a Probabilistic Approach. Advanced Engineering Materials, 26(2). https://doi.org/10.1002/adem.202300911

Readers' Seniority

Tooltip

Professor / Associate Prof. 1

33%

PhD / Post grad / Masters / Doc 1

33%

Researcher 1

33%

Readers' Discipline

Tooltip

Engineering 2

100%

Save time finding and organizing research with Mendeley

Sign up for free