To eliminate the common-mode leakage current in the transformerless grid-connected photovoltaic (PV) system, inspired by the newly-developed embedded-switch H5 topology and dual-buck full-bridge grid-connected inverter (GCI), a novel transformerless dual-buck full-bridge GCI with H5-type (TDFGI-H5) topology for PV systems is firstly presented. Then, the operating modes and common-mode leakage current of TDFGI-H5 modulated by unipolar sinusoidal pulse-width modulation are analysed. The analysis result shows that TDFGI-H5 has the advantages of the three-level output, no shoot-through problem, high reliability, and can completely meet the condition of eliminating common-mode leakage current. Aim at the problem of the common-mode leakage affected by the switches' junction capacitances, the effect of switch's junction capacitance is explored in detail when TDFGI-H5 is in the transient process that converts from non-decoupling states to decoupling states. Finally, the results of experiment verify the correctness of the theoretical analysis.
CITATION STYLE
Dai, Y., Li, W., Zhou, C., & Zhuang, S. (2019). Research on transformerless dual-buck fullbridge grid-connected inverter with H5-type for PV systems. IET Power Electronics, 12(1), 44–50. https://doi.org/10.1049/iet-pel.2018.5196