Intracranial pressure telemetry: First experience of an experimental in vivo study using a new device

11Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: To test two new telemetric intracranial pressure (ICP) probes (NEUROVENT®-P-tel, NEUROVENT®-S-tel) in a porcine model. We aimed to intraoperatively correlate the telemetric probes to parenchymal ICP probes and study their reliability in the first hours after implantation. The experimental set-up, new telemetric technology and first data will be presented. Methods: We implanted a right parietal (parenchymal) and left parietal (subdural) telemetric ICP probe in 13 Göttingen mini-pigs under general anaesthesia. Through the left parietal burr hole a parenchymal ICP probe (Neurovent® ICP) was introduced. Intraoperatively, the head position was changed to provoke ICP changes every 10 min. The telemetric probes were left in situ and finally the parenchymal ICP probe was removed. We correlated mean differences between each telemetric probe and the conventional ICP measurement and Bland-Altman plots were generated for statistical analysis. Results: We present first data containing intraoperative measurements of 26 telemetric probes after implantation. Intraoperatively, mean differences of 2.48 ± 1.52 mmHg SD (NEUROVENT®-P-tel) and 2.64 ± 1.79 mmHg (NEUROVENT®-S-tel) were observed. The Bland-Altman plot demonstrates good correlation of the telemetric probes compared with parenchymal ICP probes. Conclusion: We present a new telemetric technology that was experimentally compared with a parenchymal ICP probe. We provide data that the new telemetric probes will comparably measure ICP vs an external ICP probe. This stand-alone ICP tool may allow permanent measurement of ICP in hydrocephalus patients. Further continuation of our study will demonstrate whether this system guarantees acceptable long-term reliability. © 2012 Springer-Verlag/Wien.

Author supplied keywords

Cite

CITATION STYLE

APA

Orakcioglu, B., Beynon, C., Kentar, M. M., Eymann, R., Kiefer, M., & Sakowitz, O. W. (2012). Intracranial pressure telemetry: First experience of an experimental in vivo study using a new device. In Acta Neurochirurgica, Supplementum (Vol. 114, pp. 105–110). Springer-Verlag Wien. https://doi.org/10.1007/978-3-7091-0956-4_19

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free