Experimental study of the mechanical behavior of the steel-concrete joints in a composite truss bridge

16Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

The mechanical behavior of the steel-concrete joints in a composite bridge was investigated. Pull-out tests on eight specimens were carried out to evaluate the connection performance of Perfobond rib shear connectors (PBL shear connectors). In addition, static load tests were conducted on three composite joint specimens with a scale of 1/2 in a composite truss bridge. The crack load, load-displacement curves, strain distribution, and the joint stiffness were obtained from the composite joint to analyze the mechanical behavior of steel-concrete joints. The experimental results show that the embedded depth plays an important role in the ultimate bearing capacity and the deformation of PBL shear connectors and could even change the failure mode. Based on the test results of composite joints, the displacement increased almost linearly with the horizontal load on the concrete chord. There was no evident failure, and large deformation occurred in composite joints. In addition, the ultimate loads obtained from three composite joint specimens were greater than 2.93 times the design load (2050 kN). These investigated composite joints had excellent bearing capacity (above 6000 kN). This study will provide an experimental reference for the design of steel-concrete joints for composite truss bridges.

References Powered by Scopus

Active interface debonding detection of a concrete-filled steel tube with piezoelectric technologies using wavelet packet analysis

233Citations
N/AReaders
Get full text

Deformation limit states for circular reinforced concrete bridge columns

196Citations
N/AReaders
Get full text

Analytical model for predicting axial capacity and behavior of concrete encased steel composite stub columns

169Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Shear behavior of perfobond connectors in the steel-concrete joints of hybrid bridges

34Citations
N/AReaders
Get full text

Research on application of uplift-restricted slip-permitted (URSP) connectors in steel-concrete composite frames

25Citations
N/AReaders
Get full text

Mechanical behavior of perfobond connector group in steel–concrete joint of hybrid bridge

14Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Tan, Y., Zhu, B., Yan, T., Huang, B., Wang, X., Yang, W., & Huang, B. (2019). Experimental study of the mechanical behavior of the steel-concrete joints in a composite truss bridge. Applied Sciences (Switzerland), 9(5). https://doi.org/10.3390/app9050854