Low-power methods of power sensing and frequency detection for wideband vibration energy harvesting

0Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Power maximisation techniques in wideband vibration energy harvesting typically require the periodic sensing of input power or excitation frequency. This paper presents low- power circuits and sensing methods to obtain this information. First, an excitation frequency measurement circuit is presented that permits a reduced timer run-time compared to reported methods. Second, a power sensing method is presented, which extends the measurement range of reported techniques by adapting to the levels of the available power. Experimental results for the frequency measurement circuit tested in the range 35-51 Hz show a power consumption of 3.7 μW. The power-sensing technique is experimentally validated over a power range of 370690 μW, and its power consumption is 7.5 μW.

Cite

CITATION STYLE

APA

Proynov, P., Stark, B. H., & McNeill, N. (2014). Low-power methods of power sensing and frequency detection for wideband vibration energy harvesting. In Journal of Physics: Conference Series (Vol. 557). Institute of Physics Publishing. https://doi.org/10.1088/1742-6596/557/1/012127