In this work we present a Mesh Warping technique for the construction of patient-specific Finite Element Method models from patient MRI images, and demonstrate how simulated surgical loading can be applied to these models. We compare the results of this simulation with observed deformation during surgery, and show that our model matches well with the observed degree of deformation.
CITATION STYLE
Castellano-Smith, A. D., Hartkens, T., Schnabel, J., Hose, D. R., Liu, H., Hall, W. A., … Hill, D. (2001). Constructing patient specific models for correcting intraoperative brain deformation. In Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics) (Vol. 2208, pp. 1091–1098). Springer Verlag. https://doi.org/10.1007/3-540-45468-3_130