We report on the dynamic behavior of dual-wavelength distributed feedback (DFB) quantum cascade lasers (QCLs) in continuous wave and intermittent continuous wave operation. We investigate inherent etaloning effects based on spectrally resolved light-current-voltage (LIV) characterization and perform time-resolved spectral analysis of thermal chirping during long (> 5 μs) current pulses. The theoretical aspects of the observed behavior are discussed using a combination of finite element method simulations and transfer matrix method calculations of dual-section DFB structures. Based on these results, we demonstrate how the internal etaloning can be minimized using anti-reflective (AR) coatings. Finally, the potential and benefits of these devices for high precision trace gas analysis are demonstrated using a laser absorption spectroscopic setup. Thereby, the atmospherically highly relevant compounds CO2 (including its major isotopologues), CO and N2O are simultaneously determined with a precision of 0.16 ppm, 0.22 ppb and 0.26 ppb, respectively, using a 1-s integration time and an optical path-length of 36 m. This creates exciting new opportunities in the development of compact, multi-species trace gas analyzers.
CITATION STYLE
Süess, M. J., Hundt, P. M., Tuzson, B., Riedi, S., Wolf, J. M., Peretti, R., … Faist, J. (2016). Dual-section DFB-QCLs for multi-species trace gas analysis. Photonics, 3(2). https://doi.org/10.3390/photonics3020024
Mendeley helps you to discover research relevant for your work.