Clinical performance of two automated immunoassays, elia ctd screen and quanta flash ctd screen plus, for antinuclear antibody screening

4Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

Background: Recently, two fully automated immunoassays for antinuclear antibody (ANA) screening were introduced: EliA CTD Screen (Thermo Fisher Scientific, Freiburg, Germany) and QUANTA Flash CTD Screen Plus (Inova Diagnostics, San Diego, USA). We evaluated their clinical performance in comparison with the indirect immunofluorescence assay (IIFA) and analyzed samples with discrepant results. Methods: In total, 406 serum samples (206 from patients undergoing routine checkups and 200 from rheumatology clinic patients) were assayed using EliA, QUANTA Flash, and IIFA. We evaluated assay concordance and agreement and confirmed the presence of anti-extractable nuclear antigen (ENA) antibodies in samples with discrepant automated immunoassay and IIFA results. Additionally, we compared the clinical performance of each assay in diagnosing ANA-associated rheumatic disease (AARD) and adjusted the cut-off values. Results: In rheumatology clinic samples, the concordance and agreement were 91.5% and strong between EliA and QUANTA Flash, 79.0% and weak between EliA and IIFA, and 80.5% and moderate between QUANTA Flash and IIFA, respectively. In automated immunoassay-positive, IIFA-negative samples (N=15), all anti-ENA antibodies detected (6/15) were anti-Sjögren's syndrome antigen A/Ro (Ro60) antibodies. The automated immunoassays and IIFA showed high accuracy for diagnosing AARD, and adjusted cut-off values improved their sensitivities (EliA with 0.56 ratio, 82.9% sensitivity; QUANTA Flash with 9.7 chemiluminescent units, 87.8% sensitivity). Conclusions: The two automated immunoassays showed reliable performance compared with IIFA and can be efficiently used with the IIFA in clinical immunology laboratories. Clinical cut-off values can be adjusted according to the workflow in each laboratory.

References Powered by Scopus

Interrater reliability: The kappa statistic

13150Citations
N/AReaders
Get full text

Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests

1609Citations
N/AReaders
Get full text

2019 European League Against Rheumatism/American College of Rheumatology Classification Criteria for Systemic Lupus Erythematosus

1457Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Charting the Next Road Map for CSF Biomarkers in Alzheimer’s Disease and Related Dementias

4Citations
N/AReaders
Get full text

Immunodiagnosis of Sjögren’s Disease

0Citations
N/AReaders
Get full text

Development of Proliferating Cell Nuclear Antigen Autoantibodies With the Manifestation of Graft Versus Host Disease After Peripheral Blood Stem Cell Transplantation

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yoon, S., Moon, H. W., Kim, H., Hur, M., & Yun, Y. M. (2021). Clinical performance of two automated immunoassays, elia ctd screen and quanta flash ctd screen plus, for antinuclear antibody screening. Annals of Laboratory Medicine, 42(1), 63–70. https://doi.org/10.3343/ALM.2022.42.1.63

Readers over time

‘21‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

67%

Researcher 1

33%

Readers' Discipline

Tooltip

Psychology 2

40%

Agricultural and Biological Sciences 1

20%

Physics and Astronomy 1

20%

Computer Science 1

20%

Save time finding and organizing research with Mendeley

Sign up for free
0