Partial stator overlap in a linear generator for wave power: An experimental study

8Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

Abstract

This paper presents a study on how the power absorption and damping in a linear generator for wave energy conversion are affected by partial overlap between stator and translator. The theoretical study shows that the electrical power as well as the damping coefficient change quadratically with partial stator overlap, if inductance, friction and iron losses are assumed independent of partial stator overlap or can be neglected. Results from onshore experiments on a linear generator for wave energy conversion cannot reject the quadratic relationship. Measurements were done on the inductance of the linear generator and no dependence on partial stator overlap could be found. Simulations of the wave energy converter's operation in high waves show that entirely neglecting partial stator overlap will overestimate the energy yield and underestimate the peak forces in the line between the buoy and the generator. The difference between assuming a linear relationship instead of a quadratic relationship is visible but small in the energy yield in the simulation. Since the theoretical deduction suggests a quadratic relationship, this is advisable to use during modeling. However, a linear assumption could be seen as an acceptable simplification when modeling since other relationships can be computationally costly.

References Powered by Scopus

Wave energy utilization: A review of the technologies

2457Citations
N/AReaders
Get full text

A review of wave energy converter technology

1027Citations
N/AReaders
Get full text

Linear PM generator system for wave energy conversion in the AWS

328Citations
N/AReaders
Get full text

Cited by Powered by Scopus

A study of a speed amplified linear generator for low-frequency wave energy conversion

29Citations
N/AReaders
Get full text

Design of permanent-magnet linear generators with constant-torque-angle control for wave power

21Citations
N/AReaders
Get full text

Method for optimizing the magnetic circuit of a linear generator using FEM simulations

8Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Frost, A. E., Ulvgård, L., Sjökvist, L., Eriksson, S., & Leijon, M. (2017). Partial stator overlap in a linear generator for wave power: An experimental study. Journal of Marine Science and Engineering, 5(4). https://doi.org/10.3390/jmse5040053

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 4

57%

Professor / Associate Prof. 1

14%

Lecturer / Post doc 1

14%

Researcher 1

14%

Readers' Discipline

Tooltip

Engineering 6

67%

Energy 2

22%

Mathematics 1

11%

Article Metrics

Tooltip
Mentions
Blog Mentions: 1
Social Media
Shares, Likes & Comments: 48

Save time finding and organizing research with Mendeley

Sign up for free