Background - Patients with bicuspid aortic valve (BAV) have been frequently complicated with ascending aortic dilation possibly because of hemodynamic burdens by aortic stenosis (AS) or regurgitation (AR) or congenital fragility of the aortic wall. Methods and Results - To clarify if the aortic dilation could be prevented by aortic valve replacement (AVR) in BAV patients, we studied 13 BAV (8 AR dominant, 5 AS dominant) and 14 tricuspid aortic valve (TAV) patients (7 AR, 7 AS) by echocardiography before and after AVR (9.7±4.8 years). We also studied 18 BAV (11 AR, 7 AS) without AVR. Diameters of the sinuses of Valsalva, sinotubular junction and the proximal aorta were measured. The annual dilation rate was calculated by dividing changes of diameters during the follow-up period by the body surface area and the observation interval. We found that aortic dilation in BAV patients tended to be faster than that in TAV patients, although a significant difference was found only at the proximal aorta (0.18±0.08 versus -0.08±0.08 mm/(m2/year), P=0.03). BAV patients with and without AVR showed similar progressive dilation. AR dominant group showed tendency of more progressive dilation than AS dominant group in BAV, although it did not reach statistical significance. TAV patients did not show further aortic dilation after AVR. Conclusions - AVR could not prevent progressive aortic dilation in BAV. Since the aorta did not dilate in TAV, progressive aortic dilation in BAV seems mainly due to the fragility of the aortic wall rather than hemodynamic factors.

References Powered by Scopus

Two-dimensional echocardiographic aortic root dimensions in normal children and adults

969Citations
N/AReaders
Get full text

Evaluation of aortic insufficiency by Doppler color flow mapping

879Citations
N/AReaders
Get full text

The congenitally bicuspid aortic valve. A study of 85 autopsy cases

784Citations
N/AReaders
Get full text

Cited by Powered by Scopus

2014 AHA/ACC guideline for the management of patients with valvular heart disease: A report of the American college of cardiology/American heart association task force on practice guidelines

2320Citations
N/AReaders
Get full text

2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines

2031Citations
N/AReaders
Get full text

2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines

1456Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Yasuda, H., Nakatani, S., Stugaard, M., Tsujita-Kuroda, Y., Bando, K., Kobayashi, J., … Miyatake, K. (2003). Failure to prevent progressive dilation of ascending aorta by aortic valve replacement in patients with bicuspid aortic valve: Comparison with tricuspid aortic valve. Circulation, 108(10 SUPPL.). https://doi.org/10.1161/01.cir.0000087449.03964.fb

Readers over time

‘10‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘250481216

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 36

57%

Researcher 16

25%

Professor / Associate Prof. 10

16%

Lecturer / Post doc 1

2%

Readers' Discipline

Tooltip

Medicine and Dentistry 53

76%

Engineering 14

20%

Agricultural and Biological Sciences 2

3%

Chemical Engineering 1

1%

Article Metrics

Tooltip
Mentions
News Mentions: 1

Save time finding and organizing research with Mendeley

Sign up for free
0