Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler

9Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

This paper highlights a case study of typical premature failure of a radiant platen superheater tube of 210 MW thermal power plant boiler. Visual examination, dimensional measurement and chemical analysis, are conducted as part of the investigations. Apart from these, metallographic analysis and fractography are also conducted to ascertain the probable cause of failure. Finally it has been concluded that the premature failure of the super heater tube can be attributed to localized creep at high temperature. The corrective actions has also been suggested to avoid this type of failure in near future.

Cite

CITATION STYLE

APA

Ghosh, D., Ray, S., Mandal, A., & Roy, H. (2015). Failure Investigation of Radiant Platen Superheater Tube of Thermal Power Plant Boiler. High Temperature Materials and Processes, 34(2), 171–175. https://doi.org/10.1515/htmp-2013-0128

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free